Ringing Voltage output: Approx 120v ac (depending on device).

Ring frequency: 25Hz.

Cadences 3:

Click to Hear UK 0.4 sec On, 0.2 sec Off, 0.4 sec On, 2 seconds Off.

Click to Hear US long 2 sec On, 4 seconds Off.

Click to Hear US short 1 sec On, 2 seconds Off.

Unit Power Requirement: Regulated 12Vdc @ 500Ma

Power consumption: Approximately 5 watts.

Mains Plug-in Power Supply: Regulated 12vdc @ 500Ma with 2.5mm dc plug +ve centre pin.

Two rear Telephones sockets: The unit will support 2 telephones using sounders or bells and may be used with a long telephone extension lead.

Mouseover Photo to rotate

Warning!

Please note!

It is prohibited to connect this ringer to either a public or private exchange, there are punitive fines and irreparable damage may ensue.

Guarantee

The units are guaranteed for 1 year from date of purchase subject to the following:-

1. If faulty, the Unit is returned to Precision Vision - carriage paid and undamaged.

2. No attempt has been made to repair or tamper with the unit and a Power pack of greater than 12Vdc has not been used.

Countries not having 240v mains supply may use their own Power pack provided it meets the same specifications as above. A price reduction will be made if a Power pack is not supplied.